The thermally separated stand-off installation in external thermal insulation composite systems.

Stand-off installation TherMax 10

The fischer stand-off installation system TherMax 10 is a solution for thermally separated fixation in external thermal insulation composite systems (ETICS). The threaded rod has a glass-fibre-reinforced cone and cuts its own way through the plaster and into the insulation material without a setting tool. The cone on the head of the threaded rod interrupts the thermal bridge. The adjustable system is suitable for fixations in ETICS and non-load-bearing layers of 80 mm to 240 mm in thickness. The fischer TherMax 10 can hold medium-sized loads such as lights, letterboxes, and lightning rods in concrete, aerated concrete, and masonry made from perforated or solid brick.
Produktne varianteDownload of image data

Produktne variante

Filtro
Filtro
33 Variantes del producto
Drill diameter
Drill hole depth
Max. thickness of non-bearing layer
Anchorage depth
Cover cap-ø
Width across nut
Más resultados
Visto 18 de 33 variante (s)

Opis izdelka

Advantages
  • The stand-off installation allows for the fixture to be adjusted to the exact position required, whereby pressure marks and damage to the ETICS are avoided.
  • The plastic cone creates a thermal barrier between the fixture and the inner fixture, and offers an energy-optimised fixing.
  • The glass-fibre-reinforced plastic cone cuts its own way through the ETICS with a positive fit, and allows for a simple and fast installation without the need for any special tools.
  • Combining with the universal plug UX provides a secure anchoring in the substrate.
  • Without UX plug direct mounting in wood substrate is possible after pre-drilling.
Youtube VideoYoutube VideoYoutube Video

Dovoljenje aplikaciji

Applications
For the thermally separated fixing of:
  • Signs
  • Lighting
  • Letter boxes
  • Motion detectors
  • Downpipes
  • Lightning rods
  • Blind guide rails
Building materials
  • Concrete
  • Vertically perforated brick
  • Hollow blocks made from lightweight concrete
  • Perforated sand-lime brick
  • Solid sand-lime brick
  • Building brick
  • Aerated concrete
  • Wood
Podroben opis najdete v priloženem dokumentu

Navodila uporabe

Functionality
  • The TherMax 10 system is suitable for pre-positioned installation.
  • The self-tapping, glass-fibre-reinforced cone cuts its own way through the plaster into the insulation during installation.
  • The anti-cold cone uses a thermal barrier to minimise heat losses.
  • Installation without any special tools.
  • For use in wood without plug, the wood (footnote below load table) as well as the plaster has to be pre-drilled: TherMax 10: d02 = 18 mm, h02 = 50 mm.
  • The assortment offers connection possibilities using metric screws M6/8/10, self-tapping screws 6.3 mm, chipboard screws 6.0 mm or chipboard screws 4.5 - 5.5 mm when using a SX Plus 5 plug.
Mounting Strip 1 Picture
1 / 8
Mounting Strip 2 Picture
1 / 6

Dokumenti za prenos

Stand-off installation TherMax 8 and 10 - Recommended loads of a single anchor in concrete and masonry.
Stand-off installation TherMax 8 and 10 - Recommended tensile loads for a single anchor in wood.
Stand-off installation TherMax 8 and 10 - Recommended shear loads for a single anchor.
TherMax.
cd-blue-c6785f99-bhvvp